Anomaly Description:
A leak has been detected on the body flange of a vessel during gas regeneration process. The vessel flanges had a diameter of 2700mm.
Root causes:
A worn-out flange gasket caused gas to leak through the vessel body flanges.
The leak occurred when gas temperature increased in the regeneration cycle.
Integrity concerns:
During the regeneration cycle, both gas temperature and pressure increases causing process service to leak through the worn-out flange gasket.
Since the process service is highly corrosive, its leakage would corrode the vessel flanges and bolting system.
Corrosion of the vessel flanges and bolting system would result in weakening of the vessel’s structural integrity followed by excessive leakage of a very flammable and toxic process service.
Technical Details
Line Size:
Design Pressure:
Operating Pressure:
Design Temperature:
Operating Temperature:
Material:
Line Class:
N/A
4
1.45
440
150
A350 Gr LF2 / A 182 Gr F12
N/A