Problem Summary
Anomaly Description:
A small leak was detected on the body flange of vessel 1E-405.2. The gasket and studs are over 20 years old. The existing studs were corroded and could not be re-tightened. The existing sheet gasket is completely confined and can withstand a higher compression gasket load.
The client had completed a bolt change out of procedure, yet the leak of H2S was still present.
Root causes:
The gasket and studs that have been in service for 20 years had not been replaced and as a result were deteriorated.
Integrity concerns:
Further degradation of gasket and bolting would lead to increased exposure of H2S into the environment. H2S exposure to human health is hazardous with large amounts of exposure being fatal. There was also the risk of Stress Corrosion Cracking with the bolting being exposed to sour service.